Backflow Prevention Assembly Testers List
The Oakland County Water Resources Commissioner's (WRC) Cross Connection Control Program (CCCP) is designed to protect drinking water. It does that by preventing contaminants from entering the public water supply system through a reversal of flow (backpressure or back-siphonage).
The CCCP is run in accordance with the Michigan Department of Environment, Great Lakes and Energy (EGLE) and the State of Michigan Public Act 399, 1976 Rule #325.11401. Our program is approved by EGLE and has been in effect in Oakland County since 1976. The onset of our program focused on commercial and industrial facilities and was expanded in 2002 to include residential customers. This update occurred in response to changes in State rules and regulations in an effort to better protect our potable (drinking) water systems from pollution or contamination.

Diagram of water pipes and car striking hydrant - A drop in the water pressure due to a break in the water main cause water to flow in reverse. Contaminated water enters the main.
A cross connection is a connection or arrangement of piping or appurtenances through which backflow of non-potable water could flow into the potable drinking water supply. Backflow is defined as water of questionable quality, wastes, or other contaminants entering a potable water supply system due to a reversal of flow. Whenever there is a physical connection between a potable water system and a non-potable environment, backflow may occur from backsiphonage or backpressure. These pressure fluctuations can be caused by hydrant flushing, a water main break, a power outage, or several other factors. In order to ensure safe drinking water, backflow prevention devices or assemblies are required at all connections where the water may be exposed to a pollutant or contaminant.
Our Cross Connection Unit has a State-approved comprehensive program designed for the inspection, elimination and prevention of cross connections at all service connections including commercial, industrial and residential sites. Our staff performs these inspections, which are included in your water rates, at a minimum interval of once every one-to-10 years. If our staff finds an unprotected cross connection, the customer will be notified by mail. This letter may provide a notice to install a proper backflow prevention device or assembly or have the existing one properly installed and/or tested by a licensed and certified tester. Any repairs, installation and/or testing are the responsibility of the homeowner or business. Many backflow prevention assemblies are required to be tested (WRC test form) annually in order to ensure they are working properly. These backflow prevention assemblies have internal seals, springs and moving parts that are subject to fouling, wear or fatigue and must be maintained in proper working order.
There are many simple things each of us can do to help prevent cross connections in and around our homes or places of business. Become familiar with your water piping system. Review every water connection in the building and visualize the result if the water flow reversed. Install the necessary backflow prevention devices or assemblies and keep them maintained, tested and in proper working order.
Several examples of typical water connections to review for proper protection are garden hoses, toilets or toilet fill valves, lawn sprinkler systems, laundry tubs, swimming pools, hot tubs, boiler systems, water assisted sump pumps and fire sprinkler systems. Common hazards associated with garden hoses include the misuse of the garden hose; leaving the end of the hose submerged in swimming pools, attached to chemical sprayers or laying on the ground. Without the proper backflow prevention device or assembly these garden hoses can expose the water supply to cesspools, pesticides or garden chemicals and animal feces. If not properly protected against backflow, these water connections may cause polluted and/or contaminated water to enter the potable water supply. This can result in illness and even death.
In addition, private wells that are also connected to the potable water supply are a direct cross connection and prohibited. The piping from a well must be permanently disconnected from the potable water supply. The well may still be used as a secondary source of water if it is not in any way connected to the public drinking water supply.
Learn more about safe drinking water. Can you help Prevent a Cross Connection?
Comparison shop! Contact several companies and ask for a quote over the phone. See our WRC Backflow Prevention Assembly Tester List.
Some items to ask when contacting a company to perform the installation/repair and/or testing:
*This information is provided as a courtesy and is not intended as an endorsement or referral. The businesses provided on this website have no affiliation with the Oakland County Water Resources Commissioner's Office. You are responsible for any and all services rendered by your contractor/plumber.
All completed backflow prevention assembly test results must be submitted online by your tester. Test results will no longer be accepted via email, fax or mail.
Search for a complete list of ASSE 5110 certified professionals by state, certification, or last name.
Search for a complete list of licensed master plumbers, journeyman plumbers or apprentice plumbers by state, license number or last name.
Phone: 248-858-1431
Email:wrccrossconnection@oakgov.com
Fax: 248-858-7939
248-858-1066
One Public Works Drive
Building 95W
Waterford, MI 48328-1907
Emergency After Hours: 248-624-6366
8:00am - 4:30pm